RoughInSizing calculators for the trades

Sources and methods

Every RoughIn calculator is built from a published code table, engineering standard, government data set or manufacturer sheet. This page lists them, with the calculators that use each one. The edition each calculator follows is named on that calculator's page.

How the numbers are checked

Tables are transcribed from the source and compared with a second copy. Each calculator is then run against the source's own worked examples, such as NEC Annex C for conduit fill and the IFGC capacity tables for gas pipe, and those checks are kept as automated tests that are run again before each update goes live. Where two sources disagree, the value is left out until it can be confirmed.

Codes are adopted and amended locally, so the edition in force where you work may differ. Check results against your local code and the authority having jurisdiction.

Building, electrical and plumbing codes

NFPA 70, National Electrical Code (NEC)

National Fire Protection Association. Conductor ampacity, conduit and box fill, overcurrent protection, motor and HVAC circuits, and dwelling load calculations.

Used in: Amps to watts, Box fill, Breaker size, Conduit fill, Electrical load, Minimum circuit ampacity, Recessed lighting, Voltage drop, Watts to amps, Wire size & ampacity, kVA.

International Residential Code (IRC)

International Code Council. Framing, headers, stairs and guards, decks, roof ventilation, wall finishes and foam insulation in one- and two-family dwellings.

Used in: Attic ventilation, Baluster spacing, Concrete, Deck beam span, Deck footing, Deck joist span, Deck post spacing, Floor joist span, Garage door rough opening, Header size, Rebar, Retaining wall, Roof pitch, Roof sheathing, Roof truss, Roofing, Spray foam, Stair stringer, Stucco, Stud.

International Fuel Gas Code (IFGC)

International Code Council. Natural gas and propane pipe capacity tables and the longest-length sizing method.

Used in: Gas pipe sizing, Propane pipe sizing.

NFPA 54 National Fuel Gas Code and NFPA 58 Liquefied Petroleum Gas Code

National Fire Protection Association. The gas and LP-gas piping rules the IFGC tables are drawn from.

Used in: Gas pipe sizing, Propane pipe sizing.

International Plumbing Code (IPC) and Uniform Plumbing Code (UPC)

International Code Council and IAPMO. Gutter and roof drain sizing, and water supply pipe sizing.

Used in: Gutter and downspout size, Water pipe sizing.

International Energy Conservation Code (IECC)

International Code Council. Climate zones and insulation requirements.

Used in: AC tonnage, Heat pump size, Insulation, Recessed lighting, Spray foam.

Engineering standards and design manuals

ACCA Manual J, Manual S and Manual D

Air Conditioning Contractors of America. The residential load, equipment selection and duct design methods the HVAC estimates point to.

Used in: AC tonnage, CFM airflow, Duct size, Furnace size, Heat pump size, Mini split size, Static pressure.

ASHRAE Handbook

ASHRAE. Duct friction and airflow fundamentals.

Used in: CFM airflow, Duct size, Flex duct CFM chart, Heat pump size.

AWC Span Tables and DCA 6 deck construction guide

American Wood Council. Joist, rafter and beam spans by species and grade, and prescriptive deck framing.

Used in: Deck beam span, Deck footing, Deck joist span, Deck post spacing, Floor joist span, Rafter span, Stair stringer.

APA PRI-400 performance rated I-joists

APA – The Engineered Wood Association. Allowable I-joist spans by series, depth and spacing.

Used in: I-joist span.

OSHA 29 CFR 1926 Subpart P, Appendix B, and 1926.500

U.S. Occupational Safety and Health Administration. Maximum trench slopes by soil type, and the steep-roof fall protection threshold.

Used in: Excavation, trench & cut-and-fill, Roof pitch.

APA Panel Design Specification

APA – The Engineered Wood Association. Approximate weights of plywood and OSB panels, and H-clip spacing for roof sheathing.

Used in: Plywood.

ICPI technical bulletins

Interlocking Concrete Pavement Institute. Bedding sand depth and paver installation practice for concrete pavers.

Used in: Paver, Polymeric sand.

NWFA Installation Guidelines

National Wood Flooring Association. Cutting and grading allowances for wood flooring, straight and diagonal.

Used in: Flooring.

ASTM standards

ASTM International. Material and test standards such as A615 reinforcing bar, C926 portland cement plaster, C476 grout and E283 air leakage.

Used in: Concrete block, Rebar, Recessed lighting, Stucco, Water pipe sizing, Well pump sizing.

ICC-ES evaluation reports

ICC Evaluation Service. Published R-values for specific spray foam products.

Used in: Spray foam.

IES lighting recommendations

Illuminating Engineering Society. Light levels used for the lumen method.

Used in: Recessed lighting.

Government data

ENERGY STAR

U.S. EPA and Department of Energy. Room air conditioner sizing chart and recommended insulation levels.

Used in: AC tonnage, BTU, Heat pump size, Insulation, Mini split size.

U.S. Department of Energy

Insulation and water heater guidance.

Used in: AC tonnage, BTU, EV charging cost, Insulation, Mini split size, Water heater sizing.

NREL PVWatts

National Renewable Energy Laboratory. Solar production estimates and sun hours by location.

Used in: Solar panel output, Solar panel tilt angle, Solar payback.

U.S. Energy Information Administration (EIA)

U.S. Energy Information Administration. Average residential electricity prices by state and fuel prices.

Used in: EV charging cost, Electricity cost, Solar payback, Space heater cost.

NOAA Atlas 14 precipitation frequency data

National Oceanic and Atmospheric Administration. Rainfall intensity for gutter and downspout sizing.

Used in: Gutter and downspout size.

U.S. Environmental Protection Agency

Vehicle efficiency and water quality figures.

Used in: AC tonnage, BTU, EV charging cost, Insulation, Mini split size, Septic tank size, Water softener sizing.

Manufacturer data and other references

Manufacturers' installation instructions and product data

Clopay, Amarr, Wayne Dalton, Quikrete, Sakrete, USG, James Hardie and others. Garage door rough openings and headroom, bag yields, joint compound coverage, siding exposure, tile grout and thinset coverage, polymeric sand coverage, and the one-coat paint coverage makers print on their labels, taken from the makers' own published sheets where available.

Used in: Concrete, Concrete block, Drywall, Flooring, Garage door rough opening, Grout, Mortar, Paint, Polymeric sand, Self-leveling concrete, Siding, Tile.

University extension services

Purdue University and other land-grant extensions. Lawn seeding and overseeding rates, and landscaping rules of thumb.

Used in: Grass seed, Mulch, Recessed lighting, Septic tank size, Sod.

Caterpillar Performance Handbook

Caterpillar. Swell and loose-density figures for common soils and rock.

Used in: Excavation, trench & cut-and-fill.

Zoeller pump tables and Crane TP-410

Zoeller Pump Company and Crane Co.. Plastic-pipe friction losses and the fitting lengths used for sump pump head.

Used in: Sump pump sizing.

The Driller and BC Plumbing Apprenticeship Level 4

Pelikan (2010) and the BC Plumbing Apprenticeship program. Water flow per fixture and the peak demand table used for well sizing, and a worked example for pressure tank sizing.

Used in: Pressure tank sizing, Well pump sizing.

Asphalt industry references

Minnesota Asphalt Pavement Association, Illinois Asphalt Pavement Association and Asphalt magazine. Spread rates for asphalt and driveway build-ups.

Used in: Asphalt.

Engineering ToolBox

Bulk densities for gravel, soil and other loose materials.

Used in: Gravel, Polymeric sand, Topsoil.

Report a problem

If a result disagrees with your code book or a manufacturer's sheet, email hello@roughincalc.com with the inputs and the table you compared against.