RoughInSizing calculators for the trades

I-joist span chart

Enter the clear span and the spacing. You get every PRI series and depth that carries it, the shallowest first, and a warning on the cells where the published table does not behave the way you would expect.

APA Form Z725, Tables 1 and 240 psf live, 10 psf dead, L/480Simple and multiple span, side by side

Inputs

ft
Face of bearing to face of bearing.
Multiple span means the joist runs continuous over an interior bearing.
Floor sheathing

Check a specific joist (optional)

Result

Shallowest joist that carries it
—

Simple span table

Allowable clear spans for APA EWS Performance-Rated I-Joists, Table 1 of APA Form Z725 (the same table appears as Table 11 of the APA Engineered Wood Construction Guide). Residential floor, dead load 10 psf, live load 40 psf, live-load deflection limited to L/480. Composite floor with glue-nailed APA Rated Sheathing, and a minimum 1-3/4 in end bearing.

DepthSeriesSpacing, on centre
12″16″19.2″24″
9-1/2″PRI-2016′–2″14′–10″14′–0″13′–1″
PRI-3017′–1″15′–7″14′–9″13′–9″
PRI-4017′–9″16′–3″15′–4″14′–4″
PRI-5017′–10″16′–4″15′–5″14′–5″
PRI-6018′–8″17′–1″16′–1″15′–0″
11-7/8″PRI-2019′–3″17′–8″16′–8″15′–7″
PRI-3020′–4″18′–7″17′–7″16′–5″
PRI-4021′–2″19′–4″18′–3″16′–8″
PRI-5021′–2″19′–5″18′–4″17′–1″
PRI-6022′–2″20′–3″19′–2″17′–10″
PRI-7023′–0″20′–11″19′–9″18′–5″
PRI-8024′–6″22′–4″21′–0″19′–7″
PRI-9025′–2″22′–11″21′–8″20′–2″
14″PRI-4024′–0″21′–11″20′–6″18′–4″
PRI-5024′–1″22′–0″20′–9″19′–5″
PRI-6025′–2″23′–0″21′–9″20′–3″
PRI-7026′–1″23′–9″22′–5″20′–11″
PRI-8027′–9″25′–4″23′–10″22′–2″
PRI-9028′–7″26′–0″24′–6″22′–10″
16″PRI-4026′–7″24′–3″22′–1″19′–9″
PRI-5026′–8″24′–4″23′–0″20′–2″
PRI-6027′–11″25′–6″24′–0″22′–5″
PRI-7028′–10″26′–4″24′–10″23′–1″
PRI-8030′–9″28′–0″26′–5″24′–7″
PRI-9031′–7″28′–9″27′–1″25′–3″

Multiple span table

Table 2 of Form Z725, for a joist running continuous over an interior bearing. Same loads and the same deflection limit. Two extra conditions apply: the end spans must be 40% or more of the adjacent span, and the intermediate bearing must be at least 3-1/2 in, against 1-3/4 in at the ends.

DepthSeriesSpacing, on centre
12″16″19.2″24″
9-1/2″PRI-2017′–7″16′–1″15′–3″13′–5″
PRI-3018′–7″17′–0″16′–0″15′–0″
PRI-4019′–4″17′–8″16′–4″14′–7″
PRI-5019′–5″17′–9″16′–9″15′–7″
PRI-6020′–4″18′–7″17′–6″16′–4″
11-7/8″PRI-2021′–0″19′–2″16′–9″13′–5″
PRI-3022′–1″20′–3″18′–10″15′–0″
PRI-4023′–0″20′–5″18′–7″16′–7″
PRI-5023′–1″21′–1″19′–11″16′–1″
PRI-6024′–2″22′–1″20′–10″19′–5″
PRI-7025′–0″22′–10″21′–6″18′–6″
PRI-8026′–8″24′–3″22′–11″21′–3″
PRI-9027′–6″25′–0″23′–6″21′–10″
14″PRI-4025′–11″22′–5″20′–5″18′–3″
PRI-5026′–3″23′–11″20′–2″16′–1″
PRI-6027′–6″25′–1″23′–8″19′–9″
PRI-7028′–5″25′–11″23′–2″18′–6″
PRI-8030′–3″27′–7″25′–11″23′–11″
PRI-9031′–2″28′–4″26′–8″24′–10″
16″PRI-4027′–11″24′–2″22′–0″19′–8″
PRI-5029′–0″24′–3″20′–2″16′–1″
PRI-6030′–5″27′–9″24′–9″19′–9″
PRI-7031′–5″27′–10″23′–2″18′–6″
PRI-8033′–6″30′–6″28′–9″23′–11″
PRI-9034′–5″31′–4″29′–6″26′–7″

Where a bigger series buys you less

In the multiple-span table there are 12 cells where moving up a series at the same depth and spacing gives you a shorter allowable span. The worst is 16″ at 24″ o.c., where going from PRI-40 to PRI-50 costs you 3′–7″.

This is not a transcription slip. Both tables here were taken from two independent copies of the APA publications and they agree cell for cell, these cells included. The simple-span table has 0 such cells, which is the clue: in a continuous span the shear and the reaction at the interior bearing can govern instead of bending or deflection, and the series number alone does not tell you how a joist behaves there. Check the specific product with the manufacturer rather than assuming a higher number is always more capacity.

Depth and spacingFromSpanUp toSpanChange
9-1/2″ at 24″ o.c.PRI-3015′–0″PRI-4014′–7″−0′–5″
11-7/8″ at 19.2″ o.c.PRI-3018′–10″PRI-4018′–7″−0′–3″
11-7/8″ at 24″ o.c.PRI-4016′–7″PRI-5016′–1″−0′–6″
11-7/8″ at 24″ o.c.PRI-6019′–5″PRI-7018′–6″−0′–11″
14″ at 19.2″ o.c.PRI-4020′–5″PRI-5020′–2″−0′–3″
14″ at 24″ o.c.PRI-4018′–3″PRI-5016′–1″−2′–2″
14″ at 19.2″ o.c.PRI-6023′–8″PRI-7023′–2″−0′–6″
14″ at 24″ o.c.PRI-6019′–9″PRI-7018′–6″−1′–3″
16″ at 19.2″ o.c.PRI-4022′–0″PRI-5020′–2″−1′–10″
16″ at 24″ o.c.PRI-4019′–8″PRI-5016′–1″−3′–7″
16″ at 19.2″ o.c.PRI-6024′–9″PRI-7023′–2″−1′–7″
16″ at 24″ o.c.PRI-6019′–9″PRI-7018′–6″−1′–3″

Where continuous is worse than simple

Running a joist continuous over an interior bearing usually buys span. Sometimes it does not. There are 20 cells where the multiple-span table allows less than the simple-span table for the same joist at the same spacing, the worst being 16″ PRI-70 at 24″ o.c., which drops from 23′–1″ to 18′–6″.

Showing the cells where the difference is 6 in or more; the rest are an inch.

JoistSpacingSimpleMultipleChange
11-7/8″ PRI-2024″15′–7″13′–5″−2′–2″
11-7/8″ PRI-3024″16′–5″15′–0″−1′–5″
11-7/8″ PRI-5024″17′–1″16′–1″−1′–0″
14″ PRI-5019.2″20′–9″20′–2″−0′–7″
14″ PRI-5024″19′–5″16′–1″−3′–4″
14″ PRI-6024″20′–3″19′–9″−0′–6″
14″ PRI-7024″20′–11″18′–6″−2′–5″
16″ PRI-5019.2″23′–0″20′–2″−2′–10″
16″ PRI-5024″20′–2″16′–1″−4′–1″
16″ PRI-6024″22′–5″19′–9″−2′–8″
16″ PRI-7019.2″24′–10″23′–2″−1′–8″
16″ PRI-7024″23′–1″18′–6″−4′–7″
16″ PRI-8024″24′–7″23′–11″−0′–8″
The 12 inches almost nobody subtracts. Every span in both tables assumes the floor sheathing is glued and nailed to the joists, which makes the floor act compositely. The footnote is one line: “Spans shall be reduced 12 inches when the floor sheathing is nailed only.” Nail the deck down without adhesive and every number on this page drops by a foot. An 18 ft span at 16″ o.c. has 19 options glued and 18 nailed only.

How to read a PRI number

PRI stands for Performance Rated I-joist. The number is a capacity grade under the APA PRI-400 standard, not a dimension — a PRI-40 and a PRI-90 can both be 11-7/8″ deep. A manufacturer makes a joist, has it qualified to a PRI series, and from then on its allowable spans are the ones in these tables rather than something product-specific. That is what makes a PRI chart usable across brands.

Not every series comes in every depth. PRI-20 and PRI-30 stop at 11-7/8″, and PRI-70 through PRI-90 start there, so the shallow 9-1/2″ options top out at PRI-60 and the deep 14″ and 16″ options start at PRI-40.

Where this chart stops

  • Floors only. These are residential floor tables at 40 psf live and 10 psf dead. Roof spans are a different table with different loads, snow, slope and deflection limits.
  • Uniform loads only. A point load from a post, a bearing wall running across the joists, or a heavy tub or stair stringer puts you outside the table and into an engineered design.
  • Clear span, not overall length. Measure face of bearing to face of bearing, then add the bearing length at each end for the joist you order.
  • The manufacturer’s own table wins. A specific TJI, BCI or LPI joist has its own published spans and its own evaluation report. Where the two disagree, the one naming the product on your delivery ticket is the one the inspector will read.
  • It does not size rim board, hangers, web stiffeners or holes through the web, all of which have their own rules in the manufacturer’s guide.

Questions

What is the maximum span for an 11-7/8 I-joist?

It depends on the series and the spacing. At 16 in on centre, simple span, the APA table runs from 17 ft 8 in for a PRI-20 up to 22 ft 11 in for a PRI-90. At 24 in on centre the same joists give 15 ft 7 in and 20 ft 2 in. Those figures assume a residential floor at 40 psf live and 10 psf dead with glue-nailed sheathing; nail the sheathing without adhesive and every one of them drops by 12 inches.

Is a continuous I-joist always stronger than a single span?

No, and the published table proves it. There are 20 cells where the multiple-span table allows a shorter span than the simple-span table for the same joist at the same spacing. The worst is a 16 in PRI-70 at 24 in on centre, which goes from 23 ft 1 in simple down to 18 ft 6 in continuous. A continuous joist develops a large reaction and high shear over the interior bearing, and that can govern instead of bending or deflection.

Does a higher PRI number always span further?

In the simple-span table, yes. In the multiple-span table there are 12 cells where it does not — for example a 16 in deep joist at 24 in on centre spans 19 ft 8 in as a PRI-40 but only 16 ft 1 in as a PRI-50. Both APA publications checked here print the same values, so it is in the standard rather than a typo. Confirm the actual product with its manufacturer.

What is the difference between PRI-400 and TJI?

PRI-400 is the APA performance standard that lets different manufacturers' I-joists be graded into common series, so one span table covers all of them. TJI is Weyerhaeuser's own brand, with its own span tables and its own evaluation report. If your delivery ticket names a specific product, use that manufacturer's table; the PRI chart is for specifying or estimating before the brand is settled.

Why do I-joists span further than sawn lumber?

The flanges carry the bending and the thin web carries the shear, so the material sits where it does the most work. An 11-7/8 in PRI-40 at 16 in on centre reaches 19 ft 4 in simple span. A 2x12 of ordinary sawn lumber at the same spacing is in the 16 to 18 ft range depending on species and grade, and it is heavier, less consistent and more likely to crown or shrink.

Do I measure the clear span or the total joist length?

Clear span, face of bearing to face of bearing. The joist you order is longer, because it needs at least 1-3/4 in of bearing at each end, and 3-1/2 in over an intermediate bearing in a multiple-span layout. Ordering to the clear span leaves you with joists that will not sit on the plate.

Sources

More Carpentry calculators

Stair stringer calculator

Risers, treads, stringer length and a cut list from the total rise, checked against the IRC or IBC stair rules.

Fence calculator

Posts, pickets, rails and post-hole concrete for a wood fence, from the length of each run and the gates.

Deck board calculator

Deck boards, linear feet, screws or hidden clips for a deck of any size, straight or diagonal.

Stud calculator

Studs, plates and precut stud length for any set of walls, with corners, intersections, doors and windows, and the cost.

Header size calculator

Header size and jack studs for a door, window or garage door in a bearing wall, from IRC Table R602.7(1).

Garage door rough opening calculator

The opening to frame for any garage door size, with the headroom, side room and back room the door needs, from the manufacturers’ own instructions.

Plywood calculator

Sheets of plywood or OSB for walls, floors or any area, with waste, weight per sheet and the cost.

Floor joist span calculator

Maximum floor and ceiling joist spans by species, grade, size and spacing, worked from the AWC 2024 span tables and design values.

Rafter span calculator

Maximum rafter span for roof live or snow load, by species, grade, size and spacing, from the AWC 2024 span tables.

Deck joist span calculator

Maximum deck joist span and overhang by species, size and spacing, from the AWC DCA 6 tables, with a check of your span.

Deck beam span calculator

Maximum deck beam span for every beam size by the joist span it carries, and the posts each beam needs, from AWC DCA 6.

Deck post spacing calculator

How far apart deck posts can be for every beam and joist span, how many posts and footings a deck needs, 4x4 vs 6x6, and railing posts.

Deck footing calculator

Footing size and thickness, maximum 6x6 post height and concrete for deck posts, from AWC DCA 6 Table 4.

Baluster spacing calculator

How many balusters a railing needs and the exact gap between them, kept under the IRC's 4 inch sphere rule.

Board foot calculator

Board feet for any list of lumber, with price, plus Doyle, Scribner and International log scales.

Other trades