Roof pitch calculator

Enter a rise and run, an angle, or a pitch. You get it back in every form a roofer or framer uses, the rafter length for your span, and the roofing materials the code allows at that slope.

Exact trigonometry, no lookupRafter length to 1/16 inIRC R905 minimum slopes

Inputs

What do you know?
in
Vertical height.
in
Level distance. Any unit works if both match.

Rafter length (optional)

ft
Outside of wall to outside of wall. 0 to skip.
in
Measured level, from the wall to the end of the tail.
in
1.5 for a 2x ridge, 0 with no ridge board.

Result

Roof pitch
—
Common rafter

Roofing allowed at 6/12

Minimum slopes from the 2021 International Residential Code, Section R905. The manufacturer's instructions can ask for more, and they govern when they do.

RoofingMinimum pitchAt this pitchIRC

Roof pitch chart

Every whole pitch from 1/12 to 24/12. The rafter factor is the length of a common rafter per foot of run; the hip factor is the length of a hip or valley rafter per foot of common run.

PitchAngleSlopeRafter factorHip / valley factor

How to measure roof pitch

  1. On the roof. Hold a level flat against the roof surface, then measure straight down from its 12 in mark to the shingles. That gap in inches is the pitch: 6 in means 6/12.
  2. From the attic. Do the same against the underside of a rafter. It is safer and gives the framing pitch directly.
  3. From the ground. At a gable end, measure the height from the wall plate to the peak and half the building's width. Enter them as rise and run, in the same unit.
  4. With a digital level or phone. Read the angle off a rafter or the roof deck and use the angle mode.

The formulas

Pitch is a right triangle: rise over a run of 12. Everything else is trigonometry on that triangle, so there is nothing to look up and nothing rounded.

Pitch = rise / run x 12 Angle = arctan(pitch / 12) Slope = pitch / 12 x 100% Rafter factor = sqrt(12² + pitch²) / 12 Hip/valley factor = sqrt(2 x 12² + pitch²) / 12

The hip factor is bigger because a hip runs diagonally across the corner. For every 12 in the common rafters run, a regular hip runs 16.97 in (12 times the square root of 2), which is why framing squares print hip figures against a 17 in run.

How the rafter length is worked out

The run of each common rafter is half the span, less half the ridge board's thickness, since the rafters butt into the ridge's faces rather than meeting at its centre. Multiplying that run by the rafter factor gives the line length along the rafter's measuring line, from the plumb cut at the ridge to the plate line at the birdsmouth. The tail is the level overhang times the same factor.

A 24 ft span at 6/12 with a 2x ridge has a run of 143.25 in, so the rafter is 143.25 x 1.118 = 160.16 in, or 13' 4-3/16", to the plate. A 12 in overhang adds 13-7/16" of tail, and the board to buy is a 16 footer.

These are line lengths. Lay them out along the measuring line, and allow for the fascia, any plumb or square tail cut, and the birdsmouth seat when you mark the board.

What pitch means for the job

Pitch decides which roofing you can use. Asphalt shingles need at least 2/12, and between 2/12 and 4/12 the code requires two layers of underlayment. Below 2/12 you are into metal panels or a membrane. The table above checks every material in IRC Section R905 against your pitch.

Over 4/12 is a steep roof under OSHA. 29 CFR 1926.500 defines a steep roof as anything over 4 in 12, and on a job site that changes the fall protection rules. Most crews treat anything over about 8/12 as needing roof jacks and a harness regardless.

Questions

What is a 6/12 roof pitch in degrees?

26.57°. The angle is the arctangent of 6 divided by 12. A 4/12 roof is 18.43°, 8/12 is 33.69°, 12/12 is exactly 45°.

How do I calculate roof pitch?

Divide the rise by the run and multiply by 12. A roof that climbs 30 in over a level 60 in has a pitch of 30 / 60 x 12 = 6, written 6/12 or 6:12.

What is the minimum pitch for asphalt shingles?

2/12 under IRC R905.2.2, with two layers of underlayment required from 2/12 up to 4/12. At 4/12 and above a single layer is enough. Some manufacturers ask for more, and their instructions govern.

What is the rafter factor or pitch multiplier?

The length of rafter per unit of run. At 6/12 it is 1.118, so a rafter that runs 10 ft level is 11.18 ft long. Roofers use the same number to turn a flat footprint into true roof area.

What does 4/12 pitch mean?

The roof rises 4 in for every 12 in it runs level. That is 18.43° or a 33.3% slope, and the bottom of what most people call a conventional roof.

Is a 7/12 roof walkable?

Most roofers walk 7/12 in dry conditions with good footwear, but it is over the 4/12 line where OSHA treats a roof as steep, so fall protection rules apply on a job site. Above about 8/12, plan on roof jacks and a harness.